Draft Environmental Impact Statement for the Golden Pass LNG Terminal and Pipeline Project under CP04-386 et al. Part 1 of 2.
03/02/2005Jnofflclal FERC-Generated PDF of 20050307-0175 Issued by FERC OSEC 03/03/2005 in Docket#: - ..PUBLIC . . :. F E R C / E I S - O 1 8 0 D E. onment i im aC.tStatement .. .~;.:'.' :.:.... -;.. : ...~. ~..:~! !;:~.' ..... .. . " .". .~e~!P,in{LNG~et~.a~]ine:Project :'~::'. ":".::,;! ' . !. : .., " . : .'.: : ! :. ~ ~ ~ ~ : . . . . . . :' llkleket Ne.. . .:'.: ~ .... :. :.t . . . . ~ .. " ; .... C ~ l - O e e . ' . ".<..".:. ;":-.;.:- C!'1~-402-4~0 "+'+ " , .. : . : . . . . i I li + Federal Energy Regulatory Commission Cooperating Agencies Office of Energy Projects Washington, DC 20426 m March 2005 MAR - 3 Jnofflclal FERC-Generated PDF of 20050307-0175 Issued by FERC OSEC 03/03/2005 in Docket#: - berths, and unloading facilities capable of accommodating up to 200 LNG ships per year; a total of five all-metal, double-walled, full containment LNG storage tanks, each with a nominal working volume of approximately 155,000 cubic meters (975,000 barrels) and each with secondary containment dikes to contain 1 I0 percent of the gross tank volume; a total often shell-and-tube vaporizers, using a closed loop circulating solution and selective catalytic reduction to reduce regulated pollutants; associated LNG storage and vaporization facilities, including administrative, storage, and maintenance buildings, access roads, and a waterline; a pipeline system comprised of 77.8 miles of 36-inch-diameter mainline, 42.8 miles of 36-inch-diameter loop, and 1.8 miles of 24-inch-diameter lateral; and associated ancillary pipeline facilities, including interconnections with up to 11 existing interstate and intrastate pipeline systems. Comment Procedures and Public Meetings Any person wishing to comment on the draft EIS may do so. To ensure consideration prior to a Commission decision on the proposal, it is important that we receive your comments before the date specified below. Please carefully follow these instructions to ensure that your comments are received in time and properly recorded: Send an original and two copies of your comments to: Magalie R. Salas, Secretary Federal Energy Regulatory Commission 888 First Street, N.E., Room IA Washington, DC 20426 Reference Docket Nos. CP04-386-000 and CP04-400-000 et al.; Label one copy ofthe comments for the attention of Gas Branch 2, PJI 1.2; and 2 Jnofflclal FERC-Generated PDF of 20050307-0175 Issued by FERC OSEC 03/03/2005 in Docket#: - Mall your comments so that they will be received In Washington, DC on or before April 18, 2005. Please note that we are continuing to experience delays in mail deliveries from the U.S. Postal Service. As a result, we will include all comments that we receive within a reasonable time frame in our environmental analysis of this Project. However, the Commission strongly encourages electronic firing ...